Schoeps CCM 4 Cardioid Compact Microphone

  • Classic cardioid compact microphone
  • Flat response and strong rear rejection
  • K 5 LU cable and SGC stand mount included

From $2,394.00 USD

Brand: Categories: , Trew SKU: SCHCCM4

Schoeps CCM 4 Cardioid Compact Microphone

The Schoeps CCM 4, the best-selling compact microphone Schoeps makes, is a classic cardioid with a flat response and a pattern that holds steady across the audio range.

Sound from the front, from the sides, and from the room all comes through without coloration, with only a mild rise around 10 kHz in the diffuse field. Rejection reaches 6 dB at 90° and 20 to 30 dB at 180°. Diffuse sound is 4.8 dB down on frontal sound, so the CCM 4 picks up less of the room and is less prone to feedback. It reaches the same balance of direct and diffuse sound as an omni from 1.7 times the distance.

It suits speech, singing, and most instruments, as a spot or studio microphone or in a stereo array: an ORTF pair on the STC bar, the mid microphone in M/S, or an XY pair. Schoeps recommends the B 5 D and B 1 D windscreens, the RL extension tube, and the TR L table stand for it.

The Lemo version comes with a 5 m K 5 LU cable to XLR-3M and an SGC miniature stand mount with swivel, and it runs on P48 or P12 phantom power. Schoeps also builds the CCM 4 with a fixed 5 m cable to XLR-3M for installations. The Parabolic Disc Set option pairs it with Schoeps’ parabolic dish.

Features

  • Classic cardioid with a steady pattern
  • Flat response without off-axis coloration
  • 6 dB down at 90°, 20 to 30 dB at 180°
  • For speech, singing, and most instruments
  • XY, ORTF, and M/S stereo
  • Lemo output with K 5 LU cable to XLR-3M
  • SGC stand mount included

What's Included

  • CCM 4 compact microphone
  • K 5 LU cable, 5 m, Lemo to XLR-3M (with the Lemo version)
  • SGC miniature stand mount with swivel

Specifications

CCM 4
Pickup Pattern Cardioid
Maximum SPL (THD < 0.5%) 136 dB SPL (P48), 128 dB SPL (P12)
Maximum Output Voltage 2.6 V (8.3 dBV) into 2 kΩ
Low-Cut Filter 20 Hz, 12 dB/oct
Output Impedance 90 Ω at 1 kHz
Minimum Load Impedance 2 kΩ
Common Mode Rejection (1 kHz) Over 55 dB
Maximum Cable Length Over 400 m
RFI Shield No
Phantom Power P48 (over 40 V), P12 (over 10 V)
Current Consumption 4 mA (P48), 3.6 mA (P12)
Output Lemo (CCM L) or fixed cable to XLR-3M (CCM K), analog, 1 channel
Length 46 mm
Diameter 20 mm
Weight 45 g
Finish Matte gray
Capsule (MK 4)
Pickup Pattern Cardioid
Frequency Range 40 Hz to 26 kHz (40 Hz to 41 kHz with CMC 6xt)
Sensitivity −36.5 dB (V/Pa), 15 mV/Pa
Equivalent Noise Level (A-Weighted) 14 dB
Equivalent Noise Level (CCIR) 24 dB
Signal-to-Noise Ratio (A-Weighted) 80 dB
Maximum SPL (THD < 0.5%) 131 dB SPL with CMC 6, 135 dB SPL with CMC 1